Selec PIC101

Selec PIC101 Process Indicators







Selec Make PIC101 (48x96) | Low Cost Scalable Indicator

 

The Selec PIC101 Process Indicators/ Multifunction indicator suitable for process values indications and alarms in operation of equipment, machinery, systems or processes in a wide range of industrial applications. The controllers operate from a range of thermocouple or 2/3 wire PT100 (RTD) input sensors, or from a millivolt, 0-5Vdc, 0-10Vdc or 0/4-20mA process signal(Scalable).Selectable temperature unit : °C / °F. Versions are available with relay and analogue outputs which can be configured. The process indicator are housed in a compact square enclosure which panel mounts, and are auxiliary powered from either 24Vac/dc or 85 to 270Vac.

 

FEATURES

 

Ø   Input : J, K, T, R, S, RTD (Pt100), Linear mV: -5 to 56 mV / 0 to 100 mV | Current: 0 / 4 to 20 mA | Voltage: 0 to 10V DC

Ø   24 VDC sensor supply 

Ø   Selectable temperature unit - °C / °F 

Ø   85 to 270V AC/DC supply voltage (also available 24V DC models) 

 


We are specialized in building PLC Control Panels and we deal with SELEC Products - PLCs, Digital Electrical Panel Meters,PID Temperature Controllers,Timers,Counters,Process Indicators,Protection Relays. We will Assist you in Programming, Installation and Commissioning of PLC’s , SCADA, Touch Screen HMI’s etc., We are also Deal with SMPS,Relay Board ,Proximity Sensors, Photoelectric Sensor, Push Button, Indicator Lights, Encoders ,Pressure Sensors, Thermocouple Sensor(NABL Calibration), RTD Sensor, Contactors, MCB's, MCCB's, Wires

For a Free Quote and for datasheets mail us at sales@selectautomations.net

 

Visit us at www.selectautomations.net


Selec  PIC101 (48x96),Low Cost Scalable Indicators at low cost, ProcessIndicator CONTROLLERS(www.selectautomations.net)

The Selec PIC101 Process Indicators/ Multifunction indicator suitable for process values indications and alarms in operation of equipment, machinery, systems or processes in a wide range of industrial applications. The controllers operate from a range of thermocouple or 2/3 wire PT100 (RTD) input sensors, or from a millivolt, 0-5Vdc, 0-10Vdc or 0/4-20mA process signal(Scalable).Selectable temperature unit : °C / °F. Versions are available with relay and analogue outputs which can be configured. The process indicator are housed in a compact square enclosure which panel mounts, and are auxiliary powered from either 24Vac/dc or 85 to 270Vac

0 comments:

Post a Comment